HYAPF series nquag lim

Lus piav qhia luv luv:

Txhawm rau ua kom tau raws li qhov xav tau ntawm ntau haiv neeg ntawm cov neeg siv khoom sib txawv rau kev siv lub zog lim dej thiab txhim kho kev txawj ntse, kev yooj yim thiab kev ruaj ntseg ntawm kev tswj hwm kev sib raug zoo, lub tuam txhab tau tsim ib qho tshiab modular peb-theem active lim ntaus ntawv.

Ntau

Product Detail

Khoom cim npe

img ua

 

khoom qauv

daim ntawv thov raug
Tam sim no, cov khoom tseem ceeb tau muab faib ua ob pawg: cov khoom siv tswj kev sib haum xeeb thiab cov khoom siv hluav taws xob reactive.Cov kev lag luam koom nrog: luam yeeb, roj av, hluav taws xob fais fab, textile, metallurgy, steel, rail transit, yas kev lag luam, tshuaj, kev sib txuas lus, them chaw nres tsheb, photovoltaic kev lag luam, Municipal, tsev thiab lwm yam lag luam, cov nram qab no yog ob peb yam raug.
1. Textile kev lag luam: Lub ntsiab loads yog loj-muaj peev xwm UPS thiab computer looms.UPS muab cov khoom siv hluav taws xob zoo nrog lub zog hluav taws xob ruaj khov qhov tseeb thiab tsis tshua muaj qhov cuam tshuam tsis zoo.Txawm li cas los xij, txij li thaum UPS yog qhov tsis sib xws, lub rectifier nyob rau hauv UPS tsim ib tug loj npaum li cas ntawm harmonic tam sim no, thiaj li hais tias tus tam sim no distortion tus nqi ntawm daim phiaj sab yog siab heev, uas tsis tsuas yog ua rau harmonic pa phem rau hauv daim phiaj, tab sis kuj cuam tshuam. cov tswv yim ib txwm muaj ntawm lub reactive hwj chim txee, thiab harmonic tswj yuav tsum tau nqa tawm
2. Nyob rau hauv kev lag luam kev kho dej, lub cev muaj zog ntawm cov dej inlet twj tso kua mis yog tsav los ntawm lub zog loj zaus converter.Txij li thaum lub zaus converter yuav tsum tau nqa tawm high-power diode rectification thiab high-power thyristor inverter, vim li ntawd, tam sim no high-order harmonics yog generated nyob rau hauv lub input thiab output circuits, uas cuam tshuam rau lub hwj chim mov system.Kev thauj khoom thiab lwm yam khoom siv hluav taws xob uas nyob ib sab cuam tshuam rau kev ua haujlwm tsis zoo ntawm lub ntsuas ntsuas, thiab kev tswj hwm kev sib raug zoo yuav tsum tau ua.
3. Kev lag luam luam yeeb: Lub load yog "threshing line"."Threshing line" yog lim tawm cov impurities hauv cov nplooj luam yeeb kom tau cov nplooj ntawv luam yeeb yam tsis muaj impurities.Cov txheej txheem no yog pom tau los ntawm zaus converters thiab motors.Lub converter zaus yog ib qho loj heev harmonic qhov chaw, yog li nws coj hnyav harmonic pa phem thiab harmonic cuam tshuam rau lub system, thiab harmonic tswj yuav tsum tau nqa tawm.
4. Kev sib txuas lus tshuab kev lag luam: UPS tau dhau los ua cov khoom siv tsis tseem ceeb hauv chav computer, UPS tuaj yeem muab cov khoom thauj
Lub zog hluav taws xob zoo nrog lub zog hluav taws xob ruaj khov qhov tseeb, ruaj khov zaus, thiab tsis tshua muaj kev cuam tshuam tsis zoo, thiab tuaj yeem ua tiav lub zog tsis muaj kev cuam tshuam thaum hloov nrog static bypass.Txawm li cas los xij, txij li UPS yog qhov tsis muaj kab hluav taws xob, nws yuav tsim kom muaj ntau qhov sib haum xeeb tam sim no.Thaum daim phiaj hluav taws xob ua rau muaj kev sib haum xeeb, nws tseem cuam tshuam rau lwm yam khoom siv rhiab hauv chav computer, ua rau muaj kev cuam tshuam loj heev lossis ua rau muaj kev puas tsuaj rau kev sib txuas lus.Yog li ntawd, txhua chav sib txuas lus hauv computer yuav tsum ntsib teeb meem ntawm kev tswj hwm kev sib raug zoo.
5. Rail Transit: Txhawm rau teb rau lub teb chaws hu rau kev txuag hluav taws xob thiab kev txo qis, ib lub tuam txhab subway tau txiav txim siab siv cov inverters hauv kev tsheb ciav hlau rau kev hloov pauv hluav taws xob, thiab tib lub sij hawm coj kev sib haum xeeb ntawm cov inverters.Tom qab ib lub sij hawm ntawm kev tshawb fawb, thiaj li yuav ua tau zoo dua lub zog-txuag renovation project, pab pawg neeg txiav txim siab los ua ib tug pilot project ntawm Rail Transit Line 4. Ntawm lawv, lub zaus converter yog xaiv los ntawm cov khoom ntawm Schneider Co., Ltd. ., thiab lub zog lim dej yog xaiv los ntawm cov khoom ntawm Xi'an Xichi Power Technology Co., Ltd.
6. Metallurgical steel: Raws li kev xav tau ntau lawm, cov khoom siv nyob rau sab thib ob ntawm lub tshuab hloov hluav taws xob hauv qhov hluav taws xob qis hluav taws xob feem ntau yog lub cev muaj zog, thiab cov zaus hloov pauv hloov lub cev muaj zog ua haujlwm.Txij li cov qauv sab hauv ntawm lub zaus hloov pauv siv ntau cov khoom tsis sib xws, ntau cov kev sib haum xeeb raug tsim thaum lub sijhawm ua haujlwm.Muaj qee yam kev cuam tshuam thaum lub sij hawm dov ntawm cov phaj, thiab cov txheej txheem ntau lawm tsis tas mus li, uas ua rau muaj kev hloov pauv thiab cuam tshuam ntawm kev ua haujlwm voltage / tam sim no, thiab kev hloov pauv hauv kev ua haujlwm tam sim no kuj ua rau muaj kev sib haum xeeb tam sim no.

Technical Parameters

Nta
●Modular khoom tsim, txo ntim zoo heev, ntaus ntawv raws li tsim, xaiv, installation thiab siv;
● Peb-theem lub ntsiab Circuit Court topology: qhov hloov pauv poob yog txo los ntawm 60%, thiab qhov hloov zaus tau nce mus rau 20KHz;
Muaj zog peb-ntxhais tswj platform: Ob 32-ntsis floating-point DSPs los ntawm TI thiab ib qho FPGA los ntawm ALTERA tsim lub zog peb-ntxhais tswj qhov system, kos nrog ntse TTA kev sib raug zoo nrhiav algorithm thiab kev sib haum xeeb xam cov sij hawm tuaj yeem siab npaum li. 51, thiab kev khiav hauj lwm zaus yuav siab li 150M, uas ua kom muaj kev kub ceev thiab qhov tseeb ntawm kev sib cais sib cais;
●High-speed multi-channel sab nraud sampling system: Embedded nrog peb ob lub davhlau ya nyob twg input high-ceev 12-tus lej analog-rau-analog conversion chips (ADS8558) ntawm American TI Company, mus txog ± 10V analog input, 1.25us sampling voj voog , muaj zog teeb liab sampling peev xwm ua rau lub cuab yeej yog, ruaj khov thiab txhim khu kev qha lag luam lav;
●Original imported fais fab module: Thawj imported EasyPAC-IGBT module, txais yuav lub thib plaub tiam IGB technology, peb-theem topology, muaj qis inductance tsim thiab qis switching poob, switching zaus ncav cuag 30kHZ, thiab lub ntim yog ntau compact, lub hwj chim ceev. yog ob npaug, uas yog lub hauv paus kho vajtse rau kev ua tiav ntawm modular APF;
● Kev tswj qhov kub thiab txias: lub sijhawm saib xyuas qhov ntsuas kub ntawm peb-theem fais fab, thaum qhov kub siab tshaj qhov teeb tsa tus nqi 1, nws yuav cia li txo qhov tso zis, thiab thaum kub tshaj qhov teeb tsa tus nqi 2, nws yuav tshaj tawm ib qho ntxiv. - kub tswb, cia li kaw thiab nres them nyiaj;
● Muaj hwj chim tswj algorithm: Hongyan Power's modular APF txais tag nrho cov kev tswj digital, thiab cov kev sib raug zoo tam sim no nrhiav pom algorithm txais kev sib raug zoo nrhiav pom algorithm raws li lub sijhawm hloov pauv (down-down A algorithm), uas tuaj yeem ceev thiab raug cais txhua qhov sib haum xeeb tam sim no. tus nqi, lub sij hawm them nyiaj tau txais kev txhim kho zoo heev, thiab cov lus teb tiag tiag 10ms tiav.Cov kev tswj tam sim no tau txais qhov tam sim no qib siab resonant regulator (PR) tam sim no tswj algorithm, uas tuaj yeem ua kom lub sijhawm tiag tiag thiab qhov tseeb ntawm kev taug qab tam sim no;
● Kev paub txog kev sib raug zoo ntawm tib neeg-khoos phis tawj: Hongyan Power's modular APF txais yuav 5-nti LCD kua siv lead ua zaub kov npo.Thaum ntau lub tshuab txuas nrog rau tib lub sijhawm, lub txee lub qhov rooj txais 10-nti kov npo.Lub zog tsis zoo xws li qhov system voltage, tam sim no, THD, PF yog qhov tseeb ntawm ib nrais muag, thiab txhawb online Hloov cov kev ua haujlwm tsis zoo, kev tiv thaiv kev nplua nuj thiab kev saib xyuas kev ua haujlwm, zoo yoog mus rau qhov chaw ua haujlwm sib txawv;
●Reliable cua txias system: Nws txais lub npe nrov DC kiv cua, uas muaj qhov tsis ua hauj lwm qis heev hauv kev ua haujlwm tas mus li, thiab muaj kev ua txhaum kev ua txhaum thiab ntse huab cua ntim tswj, hloov mus rau qhov chaw ua haujlwm hnyav, thiab tiv thaiv cov cua sov. dissipation ntawm APF ntaus ntawv!
●Kev pib txawj ntse thiab pw tsaug zog muaj nuj nqi: Thaum ntau lub modules khiav nyob rau hauv parallel nyob rau hauv lub txee, lub module units yuav cia li awakened los yog dormant raws li tus nqi load.Thaum tsuas yog ib feem ntawm cov modules raug muab tso rau hauv kev ua haujlwm, lub kaw lus yuav tswj cov modules tsis tu ncua raws li lub sijhawm teem sijhawm.Kev sib hloov input, rotation pw tsaug zog.Xyuas kom meej tias txhua qhov module ua haujlwm hauv kev ua haujlwm zoo, txhim kho lub neej kev pabcuam thiab kub yam ntxwv ntawm tag nrho cov khoom siv;
● Yooj yim thiab ceev cov chaw taws teeb saib xyuas kev ua haujlwm muaj nuj nqi: Hongyan APF module tuaj yeem nruab nrog cov chaw taws teeb sib txuas lus, kom tag nrho cov cuab yeej tuaj yeem ua haujlwm nyob deb ntawm lub xov tooj ntawm tes, hloov pauv kev ua haujlwm, kev nug ua haujlwm, thiab lwm yam. Xa cov ntaub ntawv yuam kev kom pab txhawb kev tu cov cuab yeej. thiab kev tswj xyuas, tsuav yog qhov chaw ntawm lub cuab yeej muaj lub teeb liab xov tooj ntawm tes, tsis hais tus thawj coj nyob qhov twg, lub cuab yeej tuaj yeem saib xyuas, tswj thiab tswj;

Lwm yam parameter

Technical Parameters
● Muaj peev xwm voltage: 400 x (-15% ~ + 15%)V
● Ua haujlwm zaus: 50 ± 2Hz
● Ib lub tshuab tuaj yeem lim tawm cov kev sib haum xeeb tam sim no 50A: 75A100A
●Neutral kab lim peev xwm: 3 zaug theem kab RMS tam sim no
●CT: Xav tau 3 CTs (Classl.0 lossis siab dua qhov tseeb) 5VA CT thib ob tam sim no 5A
●Filtering peev xwm: THDI (tam sim no distortion tus nqi) ≤ 5%
●Module expansion peev: 12 units
● Hloov zaus: 20KHz
●Harmonic zaus yuav lim tawm: 2 ~ 50 lub sij hawm xaiv tau
● Filter degree teeb tsa: txhua qhov kev sib haum xeeb tuaj yeem teeb tsa tus kheej
● Kev them nyiaj txoj kev: harmonic thiab reactive zog tuaj yeem teeb tsa
● Lub sij hawm teb: 100us
● Lub sij hawm teb tag nrho: 10s
● Kev tiv thaiv muaj nuj nqi: daim phiaj hluav taws xob overvoltage, undervoltage, tsis ncaj ncees lawm theem, tsis muaj theem, overcurrent, busbar overvoltage, undervoltage, overheating, overcurrent, kiv cua thiab lwm yam kev tiv thaiv txhaum.
●Display muaj nuj nqi:
1. Voltage thiab tam sim no qhov tseem ceeb ntawm txhua theem, tam sim no thiab voltage waveform zaub
2. Load tag nrho tam sim no tus nqi, lim nyiaj tag nrho tam sim no tus nqi
3. Load tam sim no THD, fais fab tuag, reactive tam sim no RMS
4. Daim phiaj tam sim no THD, lub zog ua haujlwm
5. Thauj thiab daim phiaj sib haum xeeb histogram zaub
● Kev sib txuas lus muaj nuj nqi: RS485, tus qauv MODBUS raws tu qauv
●Cooling method: ntse cua txias
● Ib puag ncig: kev teeb tsa hauv tsev, tsis muaj plua plav tawm, -10 ° C ~ + 45 ° C
●Altitude: ≤1000m, qhov siab siab dua tuaj yeem siv nrog txo qhov peev xwm
● Kev tiv thaiv qib: IP20 (siab dua tuaj yeem kho tau)
●Module loj (dav, qhov tob thiab qhov siab): 446mm x 223mm * 680mm (lwm qhov ntau thiab tsawg tuaj yeem kho tau)
● Xim: RAL7035 (lwm xim tuaj yeem hloov kho)


  • Yav dhau los:
  • Tom ntej:

  • Yam khoom